Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38330519

ABSTRACT

Pentaerythrityl tetranitrate (PETN) is an established drug in the treatment of coronary heart disease and heart failure. It is assumed, that the vasodilative and vasoprotective effects of PETN also have a positive impact on pregnant patients with impaired placental perfusion and studies evaluating the effect of PETN in risk pregnancies have been carried out. In the context of these clinical trials, measuring of serum levels of PETN and its metabolites pentaerythrityl trinitrate (PETriN), pentaerythrityl dinitrate (PEDN), pentaerythrityl mononitrate (PEMN) and pentaerythritol (PE) were required. To evaluate the transfer of PETN and its metabolites (PEXN) from the mother to the fetus using samples from a human clinical trial and animal study, the present work aimed to develop a rapid and simple method to simultaneously analyze PEXN in human and ovine samples. A method employing a rapid and simple liquid-liquid extraction followed by reversed-phase (C18) liquid chromatography coupled to high-resolution mass spectrometry with negative electrospray ionization was developed and validated for the detection of PETN and PEXN in human and ovine samples. PE could only be qualitatively detected at higher concenrations. Method validation requirements, including accuracy, repeatability and intermediate precision were fulfilled in ovine and human samples for all other PEXN with exception PETriN in human samples. The recovery (RE) in ovine samples was 76.7 % ± 12 % for PEMN, 98 % ± 23 % for PEDN, 94 % ± 22 % for PETriN, in human samples RE was 59 % ± 16 % for PEMN, 67 % ± 19 % for PEDN, 71 % ± 17 %. The matrix effects (ME) in ovine samples were 90 % ± 11 % for PEMN, 70 % ± 30 % for PEDN, 107 % ± 17 % for PETriN, in human samples the ME were 93 % ± 13 % for PEMN, 84 % ± 17 % for PEDN, 98 % ± 16 % for PETriN. The limits of quantification (LOQ) in ovine samples were 1.0 ng/mL for PETriN and 0.1 ng/mL for PEMN and PEDN. The LOQs in human samples were 5.0 ng/mL for PETriN and 0.3 ng/mL for PEMN und PEDN. The newly developed method was used to analyze 184 ovine serum samples and 18 human plasma samples. In ovine maternal samples, the highest observed PEDN concentration was 3.5 ng/mL and the highest PEMN concentration was 10 ng/mL, the respective concentrations in fetal serum samples were 4.9 ng/mL for PEDN and 5.4 ng/mL for PEMN. PETriN was only detected in traces in maternal and fetal samples, whereas PETN could not be detected at all. In human maternal samples, the highest concentration for PEDN was 27 ng/mL and for PEMN 150 ng/mL. In umbilical cord plasma, concentrations of 2.3 ng/mL for PEDN and 73 ng/mL for PEMN were detected. Although the PEMN and PEDN concentrations in the human samples were several times higher than in ovine samples, neither PETN nor PETriN signals could be detected. These results demonstrated that the metabolites were transferred from mother to fetus with a slight time delay.


Subject(s)
Pentaerythritol Tetranitrate , Animals , Female , Humans , Pregnancy , Mass Spectrometry , Pentaerythritol Tetranitrate/blood , Placenta , Sheep
2.
Expert Opin Drug Metab Toxicol ; 19(8): 487-500, 2023.
Article in English | MEDLINE | ID: mdl-37615282

ABSTRACT

INTRODUCTION: Hyphenated mass spectrometry (MS) has evolved into a very powerful analytical technique of high sensitivity and specificity. It is used to analyze a very wide spectrum of analytes in classical and alternative matrices. The presented paper will provide an overview of the current state-of-the-art of hyphenated MS applications in clinical toxicology primarily based on review articles indexed in PubMed (1990 to April 2023). AREAS COVERED: A general overview of matrices, sample preparation, analytical systems, detection modes, and validation and quality control is given. Moreover, selected applications are discussed. EXPERT OPINION: A more widespread use of hyphenated MS techniques, especially in systematic toxicological analysis and drugs of abuse testing, would help overcome limitations of immunoassay-based screening strategies. This is currently hampered by high instrument cost, qualification requirements for personnel, and less favorable turnaround times, which could be overcome by more user-friendly, ideally fully automated MS instruments. This would help making hyphenated MS-based analysis available in more laboratories and expanding analysis to a large number of organic drugs, poisons, and/or metabolites. Even the most recent novel psychoactive substances (NPS) could be presumptively identified by high-resolution MS methods, their likely presence be communicated to treating physicians, and be confirmed later on.


Subject(s)
Toxicology , Humans , Gas Chromatography-Mass Spectrometry/methods , Mass Spectrometry/methods , Toxicology/methods